89REGULAR CHECKS AND MAINTENANCE WORK
A Do not operate the engine without coolant.
A To fill the radiator system and the recovery tank, use
fresh water and anti-freeze fluid.
A When the anti-freeze is mixed with water, the anti-
freeze mixing ratio must be less than 50%.
A Tighten the radiator cap properly. If the cap is loosely
or not properly fitted, overheating of the engine can
result due to coolant fluid loss.
BReplacing Fuel Hoses and Hose Clamps
Replace the hoses and clamps.
(See "Checking Fuel Line and Intake Air Line" in "EVERY
200 SERVICE HOURS")
(1) Drain plug
(1) Radiator cap
(1) Recovery tank
(2) Radiator
(A) "FULL"
(B) "LOW"
Radiator 10.5 L (2.77 US gal.)
Recovery tank 1.3 L (0.34 US gal.)
(1) Fuel lines
(2) Clamp bands

Table of Contents