KVM6000
Function Code Table
KVM6000
Function Code Table
P3 V/F Control Parameters
Function
Code
P3-00
P3-01
P3-02
P3-03
P3-04
P3-05
P3-06
P3-07
P3-08
P3-09
Parameter Name
V/F curve
selection
Multi-point
V/F frequency1
(F1)
Multi-point
V/F voltage1 (V1)
Multi-point
V/F frequency2
(F2)
Multi-point
V/F voltage2 (V2)
Multi-point
V/F frequency3
(F3)
Multi-point
V/F voltage3 (V3)
V/F Torque boost
Cut-off
frequency of
torque boost
V/F slip
compensation
Address
0300H
0302H
0301H
0304H
0303H
0306H
0305H
0307H
0308H
0309H
Setting Range
0: Linear V/F 2: Square V/F
3: 1.2-power V/F 4: 1.4-power V/F
6: 1.6-power V/F 8: 1.8-power V/F
9: Reserved 10: V/F complete separation
11: V/F half separation
0.00~P3-03
0.0~P3-04
P3-01~P3-05
P3-02~P3-06
P3-03~maximum frequency
P3-04~100%
0.1~30.0%
0.00~maximum frequency
0~200.0%
Default
0
1.00Hz
3.0%
25.00Hz
50.0%
50.00Hz
100%
1.0%
50.00Hz
0.0%
P2-22
2~10
10~500%
2
100%
P2-23
0216H
0217H
Field weakening
automatic
adjustment gain
Field weakening
integral multiple
P3-10
Over-excitation
gain
030AH
0~2.000.64
P3-11
P3-12
P3-14
0V~rated motor voltage
0~100
-
0: Digital setting (P3-15)
1: AI1 2: AI2 3: AI3
4: Pulse setting (DI5) 5: Multi-reference
6: Simple PLC 7: PID
8: Communication setting
0V
Model
dependent
-
0
P3-15
030BH
030CH
030EH
030FH
V/F oscillation
suppression gain
Reserved
Voltage source
for V/F
separation
selection
Voltage digital
setting for
V/F separation
P3-13
--
030CH
Reserved
P4 Input Terminals function
0: No function 1: Forward RUN (FWD)
2: Reverse RUN (REV) 3: Three-Wire control
4: Forward JOG (FJOG) 5: Reverse JOG (RJOG)
6: Coast to stop 7: Emergency stop
8: Fault reset (RESET)
9: External fault input
10:Terminal UP
11:Terminal DOWN
12:UP and DOWN setting clear
13:Speed control/Torque control switchover
14:Speed search start enable
15:Reserved
16:Multi-reference terminal 1
17:Multi-reference terminal 2
18:Multi-reference terminal 3
19:Multi-reference terminal 4
20:Terminal 1 for acceleration/deceleration
time selection
21:Terminal 2 for acceleration/deceleration
time selection
22:Acceleration/Deceleration prohibited
23:PID control cancel
24:PID control pause
25:PID integral pause
26:PID characteristic switching
27:PID parameter switchover
28:PID target value switchover terminal1
29:PID target value switchover terminal2
30:PID target value switchover terminal3
31:PID feedback value switchover terminal1
32:PID feedback value switchover terminal2
33:PID feedback value switchover terminal3
34:PLC pause 35:PLC status reset
36:Swing enable 37:Swing pause
38:Swing reset
P4-00
Function
Code
S1 terminal
function
Parameter Name
Setting Range
1
Default
0400H
Address
P3-16
0V~rated motor voltage
0.0~1000.0s
0V
10.0s
P3-17
0310H
0311H
Voltage
acceleration
time of V/F
separation
Voltage
deceleration
time of V/F
separation
P3-18
--
0312H
Reserved
P4-01
S2 terminal
function
2
0401H
P4-02
S3 terminal
function
30402H
P4-03
S4 terminal
function
5
0403H
P4-04
S5 terminal
function
60404H
P4-05
S6 terminal
function
80405H