EasyManua.ls Logo

KVM KVM6000 Series - U Monitoring Parameters

KVM KVM6000 Series
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 47 -
- 46 -
KVM6000
Function Code Table
KVM6000
Function Code Table
A1-15
A1-16
A1-17
A1-18
A1-19
A1-20
A1-25
Add pump
delay time
Reduce pump
delay time
Industry frequency
switch lock time
Industry frequency
switch frequency
Fixed pump
failure
solution
Reserved
03600.0s
03600.0s
0.0210.00
0.00maximum frequency
BIT0: 0:
0: Coast-stop, fault alarm, all assist
pump stop working
1: Emergency stop, fault alarm, assist
pump maintain current situation
2: Only alarm, the system continue running
-
110FH
1110H
1111H
1112H
1113H
1114H
1119H
5.0S
3.0S
0.02s
50.00Hz
0000
-
U
Setting Range
U Monitoring Parameters
Function
Code
Parameter Name
Default
Address
U-00
U-01
U-02
U-03
U-04
U-05
U-06
U-07
U-08
-
-
-
-
-
-
-
-
-
2110H
2111H
2112H
2113H
2114H
2115H
2116H
2117H
2118H
-
-
-
-
-
-
-
-
-
Set frequency
Output frequency
Output current
Input voltage
Output voltage
Bus voltage
Output power
Module temperature
reached
Mechanical speed
A1-07
A1-08
Timing rotation
frequency limit
Timing rotation the
quantity of rest
motors
0.00maximum frequency
13
1107H
1108H
50.0Hz
0.1
A1-09
A1-10
Add pump
frequency 1
Reduce pump
frequency 1
0.00maximum frequency
0.00A1-09
1109H
110AH
48.00Hz
25.00Hz
A1-11
A1-12
Add pump
frequency 2
Reduce pump
frequency 2
0.00maximum frequency
0.00A1-11
110BH
110CH
48.00Hz
25.00Hz
A1-13
A1-14
Add pump
frequency 3
0.00maximum frequency
0.00A1-13
110DH
110EH
48.00Hz
25.00Hz
Reduce pump
frequency 2
U-09
U-10
-
-
2119H
211AH
-
-
Actual output
frequency
Target torque
U-11
U-12
U-13
U-14
U-15
U-16
U-17
U-18
U-19
U-20
-
-
-
-
-
-
-
-
-
-
211BH
211CH
211DH
211EH
211FH
2120H
2121H
2122H
2123H
2124H
-
-
-
-
-
-
-
-
-
-
Output torque
Power factor angle
PID setting
PID feedback
Terminal X Status
Terminal Y Status
AI1 input value
AI2 input value
AI3 input value
Output excitation
U-21
-
2125H
-
HDI input value
U-22
U-23
U-24
U-25
U-26
U-27
U-28
U-29
-
-
-
-
-
-
-
-
2126H
2127H
2128H
2129H
212AH
212BH
212CH
212DH
-
-
-
-
-
-
-
-
A01 output value
A02 output value
HDO output value
Counter
count value
Power-on time
power-on
operation time
Accumulated time
AC drive
running state
U-30
U-31
-
-
212EH
212FH
-
-
Maximum
current
Maximum EDC
U-32
U-33
U-34
U-35
AC drive
power level
Maximum
temperature
Miniamum EDC
Rated voltage
of AC drive
-
-
-
-
-
-
-
-
2130H
2131H
2132H
2133H
U-36
U-37
U-38
U-39
Rated current
of AC drive
Software version
Communication
setting value
Main frequency
X display
-
-
-
-
-
-
-
-
2134H
2135H
2136H
2137H
U-40
Auxiliary frequency
Y display
--
2138H
U-41
Remaining
running time
--