5. FUEL SYSTEM
5-6
ATV 50
Remove the two carburetor lock nuts.
Remove the carburetor.
AUTO BYSTARTER
AUTO BYSTARTER INSPECTION
Measure the resistance between the auto
bystarter wire terminals.
Resistance:5 (10 minutes minimum after
stopping the engine)
If the resistance exceeds 5, replace the auto
bystarter with a new one.
After the engine stops for 30 minutes,
connect a hose to the fuel enriching circuit
and blow the hose with mouth.
If air cannot be blown into the hose
(clogged), the auto bystarter is faulty.
Replace it with a new one.