2T6/2T7/2T8/2T9
1-5-20
[60/50/45 ppm model]
8. Remove the screw and then remove the
fuser unit forward.
9. Check or replace the fuser unit and refit
all the removed parts.
Caution: when refitting the fuser unit, per-
form the following procedures.
(1)Turn on the power switch while opening the
rear cover after removing the fuser unit.
(2)Turn off the power switch after 5-second or
more progress.
(release state of fixing pressure)
(3)Refit the fuser unit.
Figure 1-5-31
Fuser unit
Screw