2K3/2L3
1-5-25
4. Remove four screws and then remove
the scanner cover.
Figure 1-5-41
5. Remove the FFC from the connector.
6. Remove four screws and then remove
the image scanner unit.
7. Check or replace the image scanner
unit and refit all the removed parts.
Figure 1-5-42
Screw
Screw
Screw
Screw
Scanner cover
Screw
Screw
Screw
Screw
Image scanner
unit(ISU)
FFC
Connector