2HA/2HB
1-4-21
(1) No image appears (entirely white).
(2) No image appears (entirely black).
Copy example Causes Check procedures/corrective measures
No trans-
fer charg-
ing.
The connector terminals 
of the high-voltage PWB 
make poor contact.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, remedy or replace the cable.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective high-voltage 
PWB.
Replace the high voltage PWB and check for correct opera-
tion.
No LSU 
laser is 
output.
Defective laser scanner 
unit.
Replace the laser scanner unit (see page 1-5-19).
Defective main PWB. Replace the main PWB and check for correct operation.
No devel-
oping bias 
is output.
The connector terminals 
of the high-voltage PWB 
make poor contact.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, remedy or replace the cable.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective high-voltage 
PWB.
Replace the high voltage PWB and check for correct opera-
tion.
Copy example Causes Check procedures/corrective measures
No main 
charging.
Broken main charger 
wire.
Replace the main charger unit (see page 1-5-25).
Leaking main charger 
housing.
Clean the main charger wire, grid and shield.
The connector terminals 
of the high-voltage PWB 
make poor contact.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, remedy or replace the cable.
Defective engine PWB. Check if YC9-5 on the engine PWB goes low when mainte-
nance item U100 is run. If not, replace the engine PWB.
Defective high-voltage 
PWB.
Check if main charging takes place when YC1-12 on the 
high-voltage PWB goes low while maintenance item U100 is 
run. If not, replace the high-voltage PWB.
Exposure 
lamp fails 
to light.
The connector terminals 
of the exposure lamp 
make poor contact.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, remedy or replace the cable.
Defective inverter PWB. Check if the exposure lamp lights when YC1-1 and 1-6 on 
the inverter PWB go low while maintenance item U061 is run. 
If not, replace the inverter PWB.
Defective engine PWB. Check if YC17-1 and YC17-6 on the engine PWB goes low 
when maintenance item U061 is run. If not, replace the 
engine PWB.