2FB/2FC-3
1-4-59
U326
Setting the black line cleaning indication
Description
Sets whether to display the cleaning guidance when detecting the black line.
Purpose
Displays the cleaning guidance in order to make the call for service with the black line decrease by the rubbish
on the contact glass when scanning from the DP.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: ON
Setting count value is displayed only if the setting is ON.
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Setting the count value
1. Enter a three-digit value using the # or * key, or numeric keys. and then press the start key. The value is
set.
The setting value x 1000-sheet is possible for a display setting count value.
When reading a display setting count value is done, black line cleaning indication is displayed in auto-
matically. If the black line is detected, black line cleaning guidance is displayed in automatically when
reading the a display setting count value is done from that point.
When setting is 0, the black line cleaning indication is displayed only if the black line is detected.
2. To clear the count, press the reset key and then press the start key. The count is cleared and the screen
for selecting a maintenance item is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U327
Setting the drawer heater ON/OFF
Description
Sets ON/OFF of the drawer heater and optional side feeder dehumidifier.
Purpose
To change the setting when dew condensation on the drum is heavy.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: Drawer heater OFF, side feeder dehumidifier OFF
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Setting for U327 and U339
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display Description
ON Displays the cleaning guidance
OFF Not to display the cleaning guidance
COUNT Setting counts of the cleaning guidance indication
Display Description
CASSETTE ON Drawer heater ON
CASSETTE OFF Drawer heater OFF
SIDE FEEDER ON Side feeder dehumidifier heater ON
SIDE FEEDER OFF Side feeder dehumidifier heater OFF
U327 U339 Description
ON ON Drawer heater/dehumidifier heater ON for the sleep mode.
OFF OFF Drawer heater/dehumidifier heater OFF for the sleep mode.
OFF ON/OFF Drawer heater/dehumidifier heater OFF for the sleep mode.