2FB/2FC-4
1-5-37
C5600 Drum surface potential problem 1
Grid voltage at 4.5 V could not deter-
mine the potential.
Potential adjustment in 30 times could
not raise the potential sensor value to
the predetermined.
Deteriorated main
charger.
Check the main charger wire and replace it if
necessary (see page 1-6-33).
Grid or main
charger shield is
dirty.
Clean the grid or main charger shield if nec-
essary.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
C5610 Drum surface potential problem 2
Grid voltage at 0.3 V could not deter-
mine the potential.
Potential adjustment in 30 times could
not lower the potential sensor value to
the predetermined.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective drum. Replace the drum (see page 1-6-56).
Defective engine
PWB.
Replace the engine PWB.
C6000 Fuser heater lamp break
The fuser temperature does not
increase for 40 s after the fuser heat-
ers have been turned on for warming
up.
The fuser temperature remains below
50
°C/122 °F for 10 s continuously
after the fuser heaters have been
turned on during stabilization.
Installation defec-
tiveness on fuser
thermistor M and S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermostat.
Replace the fuser thermostat (see page 1-6-
75).
Installation defec-
tiveness on fuser
heater L, M or S.
Check the mounting state of the fuser ther-
mistor L, M and S. If any problem is found,
repair it.
Broken fuser
heater L, M and S
wire.
Check for continuity. If none, replace the
fuser heater L, M and S (see page 1-6-76).
Defective engine
PWB.
Replace the engine PWB.
Defective AC
power source
PWB.
Replace the AC power source PWB.
C6020 Fuser thermistor high-temperature
detection error
The fuser temperature exceeds 235
°C/455 °F for 10 s.
The fuser high-temperature signal is
detected for continous 500 ms.
Installation defec-
tiveness on fuser
thermistor M and S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermistor M and
S.
Replace the fuser thermistor M and S (see
page 1-6-75).
Defective engine
PWB.
Replace the engine PWB.
Code Contents
Remarks
Causes Check procedures/corrective measures