EasyManua.ls Logo

Kyocera TASKalfa 306ci - Page 33

Kyocera TASKalfa 306ci
430 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2R4/2R5/2R6
6-32
* :When the setting value is increased, the image moves backward, and it moves forward
when the setting value is decreased.
Figure 6-4
6.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034 > U066 (P.6-240) > U071 (P.6-244)
Adjustment: LSU Out Left
1.Select the item to adjust.
2.Press the [System Menu/Counter] key.
3.Press the [Start] key to output a test pattern.
4.Press the [System Menu/Counter] key.
5.Press the [Ż] [Ź] keys or the numeric keys to change the counter value.
For the test pattern 1, increase the value.
For the test pattern 2, decrease the value.
Items Contents Setting range Initial
setting
Data
varia-
tion
MPT Adjust the center line for the MP tray -3.0 to 3.0 0 0.1mm
Cass1 Adjust the center line for cassette 1 feed -3.0 to 3.0 0 0.1mm
Cass2 Adjust the center line for cassette 2
(Optional unit) feed
-3.0 to 3.0 0 0.1mm
Cass3 Adjust the center line for cassette 3
(Optional unit) feed
-3.0 to 3.0 0 0.1mm
Cass4 Adjust the center line for cassette 4
(Optional unit) feed
-3.0 to 3.0 0 0.1mm
Duplex Adjusting the center line when duplex
copying (Back page)
-3.0 to 3.0 0 0.1mm
A
A
A
Center line
(within ± 1.0 mm)
Correct image
Output
example 1
Output
example 2