EasyManua.ls Logo

Kyocera TASKalfa 520i - Page 193

Kyocera TASKalfa 520i
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2KR/2KS
1-4-35
C6040 Fuser thermistor 1 detection error
Fuser thermistor 1 detected an abnormal
value for at least 1 s.
Installation defec-
tiveness on fuser
thermistor 1.
Check the mounting state of the fuser ther-
mistor 1. If any problem is found, repair it.
Defective fuser
thermistor 1.
Replace the fuser thermistor 1.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
C6050 Abnormally low fuser thermistor tem-
perature
Fuser thermistor 1 is detected 80°C/
176°F less than 1 s continuously during
copying.
Defective fuser
heater 1 or 2.
Replace the fuser heater 1 or 2.
Installation defec-
tiveness on fuser
thermistor 1.
Check the mounting state of the fuser ther-
mistor 1. If any problem is found, repair it.
Defective PWB. Replace the power source PWB or engine
PWB and check for correct operation.
C6400 Zero-cross signal error
While fuser heater ON/OFF control is
performed, the zero-cross signal is not
input within 3 s.
Defective PWB. Replace the power source PWB or engine
PWB and check for correct operation.
C6410 Fuser unit connector insertion prob-
lem
Absence of the fuser unit is detected.
Fuser unit connec-
tor inserted incor-
rectly.
Reinsert the fuser unit connector if neces-
sary.
Defective fuser unit
connector.
Replace the fuser unit.
C7300 Toner container problem
Toner level is not detected when toner
empty is detected.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC5 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective toner
container sensor.
Replace the toner container sensor.
C7400 Developing unit connector insertion
problem
Absence of the developing unit is
detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Defective develop-
ing unit connector.
Replace the developing unit.
C7410 Drum unit connector insertion prob-
lem
Absence of the drum unit is detected.
Drum unit connec-
tor inserted incor-
rectly.
Reinsert the drum unit connector if neces-
sary.
Defective drum unit
connector.
Replace the drum unit.
C7800 Broken external thermistor wire
The thermistor output value is 4.5 V or
more.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC10 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective humidity
sensor.
Replace the humidity sensor.
Code Contents
Remarks
Causes Check procedures/corrective measures

Table of Contents

Related product manuals