EasyManua.ls Logo

L3 FA5000 - Page 51

L3 FA5000
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
Model FA5000
Initital Issue Page 9
Sep. 30/11
Description and Operation
23–7040
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
C7 ARINC429_RCV_B1 I Standard ARINC 429 differential input –
Bside. Assigned to ATC Digital Input.
Referenced to the Signal Ground.
D8 ARINC429_RCV_A2 I Standard ARINC 429 differential input –
Aside. Referenced to the Signal
Ground. Not used in the FA5001, cir
cuitry not populated on AI PWA (ARINC
429 differential input floating).
C8 ARINC429_RCV_B2 I Standard ARINC 429 differential input –
Bside. Referenced to the Signal
Ground. Not used in the FA5001, cir
cuitry not populated on AI PWA (ARINC
429 differential input floating).
D9 ARINC429_RCV_A3 I Standard ARINC 429 differential input –
Aside. Reserved, possible assignment
as GMT input. Referenced to the Signal
Ground.
C9 ARINC429_RCV_B3 I Standard ARINC 429 differential input –
Bside. Reserved, possible assignment
as GMT input. Referenced to the Signal
Ground.
D10 ARINC429_RCV_A4 I Standard ARINC 429 differential input –
Aside. Referenced to the Signal
Ground. No circuitry exists on the AI
PWA to support this signal.
C10 ARINC429_RCV_B4 I Standard ARINC 429 differential input –
Bside. Referenced to the Signal
Ground. No circuitry exists on the AI
PWA to support this signal.
C6 ARINC429_XMT_A1 O Standard ARINC 429 differential output –
Aside. Reserved, possible assignment
as OMS output. Referenced to the Sig
nal Ground.
D6 ARINC429_XMT_B1 O ARINC 429 differential output – Bside.
Reserved, possible assignment as OMS
output. Referenced to the Signal
Ground.
C5 ARINC429_XMT_A2 O Standard ARINC 429 differential output –
Aside. Referenced to the Signal
Ground. No circuitry exists on the AI
PWA to support this signal.
D5 ARINC429_XMT_B2 O Standard ARINC 429 differential output –
Bside. Referenced to the Signal
Ground. No circuitry exists on the AI
PWA to support this signal.
The document reference is online, please check the correspondence between the online documentation and the printed version.