EasyManua.ls Logo

L3 FA5000 - Page 53

L3 FA5000
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
Model FA5000
Initital Issue Page 11
Sep. 30/11
Description and Operation
23–7040
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
E6 Discrete_Input7 I Conditioned ERASE CVR INPUT A
series discrete input to the 12bit ADC
converter. The discrete state is determ
ined as high or low by comparison to in
ternally programmed thresholds. Refer
enced to the Signal Ground.
G5 Discrete_Input8 I Not Used. Conditioned DATA LINK VAL
ID shunt discrete input to the 12bit ADC
converter. The discrete state is determ
ined as high or low by comparison to in
ternally programmed thresholds. Refer
enced to the Signal Ground. Circuitry not
populated on the AI PWA. Input remains
pulled high on the AI PWA.
F5 Discrete_Input9 I Conditioned PUSH TO TEST shunt dis
crete input to the 12bit ADC converter.
The discrete state is determined as high
or low by comparison to internally pro
grammed thresholds. Referenced to the
Signal Ground.
E5 Discrete_Input10 I Not Used. Conditioned shunt discrete
input to the 12bit ADC converter. The
discrete state is determined as high or
low by comparison to internally pro
grammed thresholds. Referenced to the
Signal Ground. Circuitry not populated
on the AI PWA. Input remains pulled
high on the AI PWA.
G4 Discrete_Input11 I Not Used. Conditioned shunt discrete
input to the 12bit ADC converter. The
discrete state is determined as high or
low by comparison to internally pro
grammed thresholds. Referenced to the
Signal Ground. Circuitry not populated
on the AI PWA. Input remains pulled
high on the AI PWA.
F4 Discrete_Input12 I Not Used. Conditioned shunt discrete
input to the 12bit ADC converter. The
discrete state is determined as high or
low by comparison to internally pro
grammed thresholds. Referenced to the
Signal Ground. Circuitry not populated
on the AI PWA. Input remains pulled
high on the AI PWA.
The document reference is online, please check the correspondence between the online documentation and the printed version.