Installation and Operation Instructions Document 1342E
H2375000E
WARNING
If the information in this manual is not
followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
nearby phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a qualied installer, service agency, or gas
supplier.
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualied in hot water boiler and heater installation and maintenance. Improper installation and/or operation
could create carbon monoxide gas in ue gases which could cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.
AVERTISSEMENT
Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion
ou pour éviter tout dommage matériel, toute
blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ou ni
d’autres vapeurs ou liquides inammables dans
le à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones dans le bâtiment vous vous
trovez.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le sservice des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualié
ou par le fournisseur de gaz.
Installation and Operation
Instructions for
MASCOT
®
FT
Wall-Mounted, Modulating
Gas, Condensing, Heating Only, Boiler
Model MFTHW
Natural Gas (NG) - Factory Conguration
Propane Gas (LP) - Field-Convertible
80,000 BTU/hr
100,000 BTU/hr
120,000 BTU/hr
140,000 BTU/hr
199,000 BTU/hr

Table of Contents

Questions and Answers

  • E
    esmithAug 19, 2025
    What to do if Laars MFTHW199 burner does not ignite when hot water is opened?
    • E
      Elizabeth JensenAug 19, 2025
      If the burner on your Laars Boiler doesn't ignite when you open the hot water tap, there are several things to check: * Ensure the ON/OFF button on the Control Display is turned ON. * If the Control Display is blank, verify the power cord is plugged in and the 4A fuses on the main controller are intact. * Confirm that water is being supplied to the unit, as it activates when the inlet water flow exceeds 0 gpm. * Check that the cold and hot water lines are correctly plumbed and not reversed. * Make sure both the cold water and gas supply lines are open. * Ensure the water lines are not frozen.
  • V
    vmorganAug 21, 2025
    Why is the water from my Laars MFTHW199 not hot enough?
    • J
      Jeremy JenkinsAug 21, 2025
      If the water from your Laars Boiler isn't hot enough, consider the following: * Check the temperature setting on the unit to ensure it's not set too low. * Inspect the filter in the cold water supply line for clogs from debris. * Verify that the gas supply type is correct for your unit. * Ensure the supply and manifold gas pressures align with the specified requirements. * Confirm the water flow sensor, which has three wires, is properly connected on top of the heat exchanger.
  • C
    craig78Aug 23, 2025
    What to do if water is too hot in Laars MFTHW199 Boiler?
    • K
      kellysuttonAug 23, 2025
      If the water from your Laars Boiler is too hot, take these steps: * Verify that the temperature setting on the unit is not set too high. * Check the filter in the cold water supply line to ensure it's free of debris. * Confirm that the gas supply type being used is correct for the unit.
  • Z
    zwardAug 26, 2025
    Why does my Laars MFTHW199 Boiler make abnormal sounds during operation?
    • B
      Brittney WoodAug 26, 2025
      Abnormal sounds from your Laars Boiler during operation can be due to several reasons: * A leak of combustion gas between the sealed chamber and exhaust tube inside the unit. * Improper venting termination. * Insufficient gas pressure, which can cause an unstable burner flame and noise. Make sure that the venting termination complies with specifications and check the supply gas pressure is sufficient. If there is a leak of combustion gas, call a qualified service technician for evaluation.
  • T
    Thomas PhelpsAug 28, 2025
    Why does the hot water temperature fluctuate in my Laars Boiler?
    • T
      thomasdanielAug 28, 2025
      If the hot water temperature from your Laars Boiler fluctuates at the tap, consider these factors: * Ensure the filter in the cold water supply line is clean. * Verify the gas supply type is correct. * Check that the supply gas pressure is sufficient.
  • J
    Julia SmithAug 30, 2025
    What to do if Laars MFTHW199 is operating but nothing is shown on the control display?
    • E
      elijah46Aug 30, 2025
      If your Laars Boiler is operating but the Control Display shows nothing, the issue might be: * Lost communication from the control to the display. Check for loose connections and proper pin alignment/engagement on the Control's plug. You can also try cycling the power off and on using the boiler power switch to see if the display starts working again.
  • E
    Elizabeth StaffordSep 1, 2025
    Why is my Laars MFTHW199 Boiler blower running at full speed with nothing on the display?
    • L
      Leah BrownSep 1, 2025
      If the Control Display of your Laars Boiler shows nothing and the blower is running at full speed, it could indicate: * The control is not receiving power. Check the wiring for any short circuits or incorrect connections. Also, check the transformer connection to the control, referring to the wiring diagram, and ensure there is a 12V output from the transformer.
  • R
    Raymond FryeSep 4, 2025
    What causes Laars MFTHW199 temperature to rise too quickly?
    • E
      Eduardo WalkerSep 4, 2025
      A rapid temperature increase in your Laars Boiler occurs when the supply water temperature in the heat exchanger rises faster than 2°F per second during the first two minutes the burner is on. This issue usually resolves itself after a short delay, or you can manually reset it on the Control Display. Look for a message related to the TEMPERATURE SENSOR and follow the instructions for checking loose connections.
  • T
    Tanya PettySep 6, 2025
    What does BLOWER FAULT mean on my Laars Boiler?
    • J
      Jeremy DonovanSep 6, 2025
      A BLOWER FAULT on your Laars Boiler indicates that the blower is either unable to reach the required speed or does not reach 0 RPM when turned off. To resolve this, reset the system using the manual reset screen on the Control Display.
  • H
    holmeswilliamSep 8, 2025
    Why is the Laars MFTHW199 blower still operating after combustion stops?
    • J
      Jason HillSep 8, 2025
      It's normal for the blower in your Laars Boiler to continue running for about 1 minute after combustion stops. This allows it to vent (exhaust) the flue gas from the chamber.

Summary

Section 2: Product Characteristics

2.2 Specifications

Details the technical specifications for various MBH models of the Mascot FT boiler.

Section 3: Safety Regulations

3.2 Safety Precautions and Proper Use

Outlines essential safety precautions for operating the boiler and proper usage guidelines.

Section 4: Installation

4.9 Gas Supply and Piping

Covers requirements for gas supply piping, sizing, installation, and pressure testing.

Section 5: Control Display and Operation

5.5 CH Set Point Change Mode

Details how to change the Central Heating (CH) set-point temperature using the control display.

5.7 Installer Mode

Guides qualified technicians on accessing and adjusting installer parameters for system configuration.

Section 6: Error Codes

6.1 Error Codes

Lists error codes, their descriptions, possible remedies, and recovery methods for troubleshooting.

Section 7: Trouble Shooting

7.1 Diagnostics

Offers a Q&A format for common boiler operation issues and their potential causes.

7.2 Suggested Corrective Actions

Provides a table of faults, conditions, diagnostics, and corrective actions for troubleshooting.

Section 8: Maintenance

Section 9: Installation Check