90038900rev00
- 8 -
Treatment of chemical substances:
Use appropriate safety measures. Always refer to the data
sheets on safety and to the labels on the product used.
Use the PPEs recommended in the safety data sheets.
The operator must work on the machine when wearing PPEs
If technical assistance is required, all information indicated on
the ID plate must be provided, as well as detailed information
about the fault to make it easier for the support service to
understand and resolve the problem.
The oven power supply must have omnipolar mains switch
with a minimum opening distance between the contacts of
at least 3 mm per pole.
The oven must be part of an equipotential bonding system.
This connection is made by attaching a conductor with a nominal
section of up to 10 mm
2
to the specic terminal, located on the
rear of the oven, marked with the international symbol IEC60417
– 5021 .
The connection is made between all the adjacent devices in
the room and the dispersion system in the building.
This manual, can be downloaded in various languages using
the QR-codes shown on the specications plate.
GENERAL WARNINGS