CHAPTER 4 FAULT ALARMS
NT_820_910_1300_LX_ANG_V1 04_2007.doc
49
2.7 FAULT N°7 LEVEL FAULT.
F A U L T N ° : 0 7
F I X TO LEVEL
Fix to Level Definition :
After achieving the proper water level during the Filling Time, the
water level has dropped causing the pressurestat to open times to
indicate fluctuation of the water level in the machine.
Corrective Action :
Check if you have a leak or if the emptying tube is out of location.
2.8 FAULT N°8 PRESSURESTAT FAULT.
F A U L T N ° : 0 8
P R E S S O S T A T F A U L T
Pressostat Fault Definition :
The pressurestat has a N.O. + N.C. contact. This alarm indicates that
the contacts are both closed or both open at the same time which is not
correct.
Corrective Action :
Check the state of the pressurestat