E-1
E: Specifications
E.1 Power Specifications
The MSS power cube adaptor has the following specifications:
Adapter input voltage:
110 VAC US, 220 VAC International
Adapter output voltage:
5 VDC at 700 mA
Operating current:
700 mA @ 5 V
Power consumption:
4.2 Watts maximum
E.2 Environmental Information
E.2.1 Temperature Limitations
Operating range:
5˚ to 50˚ C (41˚ to 122˚ F)
Storage range:
-40˚ to 66˚ C (-40˚ to 151˚ F)
Max temp change:
20˚ C (36˚ F) per hour
Rapid temperature changes may affect operation. Do not operate the MSS near heating or
cooling devices, large windows, or doors that open to the outdoors.
E.2.2 Relative Humidity Limitations
Operating range:
10% to 90% noncondensing, 40% to 60% recommended
Storage range:
10% to 90% noncondensing