Integral T process thermostats
100 Technical Data YAWE 0026 / 21/01/2019
Refrigerant and filling quantity
The device contains fluorinated greenhouse gases.
Unit
T 1200
T 1200 W
T 2200
T 2200 W
Refrigerant
---
R-404A
R-404A
R-404A
R-404A
maximum filling quantity
kg
1.1
0.7
1.3
0.7
GWP
(100a)
*
---
3922
3922
3922
3922
CO
2
equivalent
t
4.3
2.7
5.1
2.7
Unit
T 4600 (W)
T 7000 (W)
T 10000
T 10000 W
Refrigerant
---
R-404A
R-404A
R-404A
R-404A
maximum filling quantity
kg
2.5
3.5
5.0
3.5
GWP
(100a)
*
---
3922
3922
3922
3922
CO
2
equivalent
t
9.8
14
20
14