22
ENGLISH
“Step-by-step” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. During the slow-down phase, at the end of the
two work times have operated for both motors, the gate stops. The operating cycle is completed (blinker off) and the system waits for a new start
command to determine the closing cycle. If a start command is supplied when the end of travel has not been reached yet the gate stops. A new start
command will cause the reversal of the motion.
“Automatic” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. During the slow-down phase, at the end of the
two work times have operated for both motors, the gate stops. The pause period starts (blinker off). At the end of the pause period the gate closes
automatically. The operating cycle is complete only when the closing motion has ended. If a start command is supplied before the end of travel is
reached the gate stops. A new start command will cause the gate to reverse its motion. If a start command is supplied during the pause period the
operating cycle is interrupted and the gate does not close automatically. A further start command will determine a closing cycle.
“Condominium” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. During the slow-down phase, at the end of the
two work times have operated for both motors, the gate stops. The pause period starts (blinker off). At the end of the pause period the gate closes
automatically. The operating cycle is complete only when the closing motion has ended. If a start command is supplied while the gate opens, the
command will have no effect. If a start command is supplied while the gate closes, the gate will stop and reverse its motion after approx. 1.5 sec. If a
start command is supplied during the pause period, the period will be reset and the automatic closure will start later.
Important : If the gate opening is controlled by a clock the “condominium” mode must be enabled.
Single-wing gate
The electronic card automatically detect the presence of a single-wing gate. In such way only the M2 motor works (terminals 13-14), and the shutter
must be connected to it. The operating modes described above remain unchanged. The Start control on the terminal board J1 will act only on the M2
motor. The Pedestrian Start is equivalent to the Start command.
Photo-cell : This device has effect only during the closure phase or in the pause period. If an obstacle covers the photo-cell during the closure phase ,
the gate stops and reverses its motion after approx. 1,5 sec. If an obstacle covers the photo-cell during the pause period this last one is reset and the
automatic closure is therefore delayed.
Pedestrian start: The Pedestrian Start command operates in the same way as the other Start command, but in this case only the (M2) wing will be
opened or closed. The Pedestrian Start command has no effect during a start cycle and up to the end of the closing phase (closed gate). During a
Pedestrian Start cycle the Start command is always active and causes the start of an opening cycle for both wings.