UPS user manual
Manuel de l’utilisateur de l’ASI
Utilizzo dell’UPS
Rev.
Descrizione
Description
Data
Date
Emesso
Issued
Approvato
Approved
Lingua
Language
Pagina
Page
di Pag.
of Pag.
B VR 31-17 17.02.17 R. Soldani G. Senesi
E/I 1 164
Codice / Code
OMG38225
UPS USER MANUAL
MANUEL DE LUTILISATEUR DE LASI
UTILIZZO DELLUPS
Index / Indice
ENGLISH LANGUAGE ................................................................................... 9
1
SCOPE ................................................................................................... 11
2
SAFETY RULES AND WARNINGS ....................................................... 12
3
GENERAL UPS DESCRIPTION ............................................................. 13
3.1 TYPOLOGY ..................................................................................................................... 13
3.2 SYSTEM DESCRIPTION ................................................................................................. 13
3.2.1 Rectifier ................................................................................................................... 13
3.2.2 Inverter .................................................................................................................... 14
3.2.3 Battery and battery charger ................................................................................... 14
3.2.4 Static bypass ........................................................................................................... 14
3.2.5 Manual bypass ........................................................................................................ 14
3.3 OPERATING STATUS ..................................................................................................... 15
3.3.1 Normal operation .................................................................................................... 15
3.3.2 Green Conversion ................................................................................................... 15
3.3.3 Bypass operation .................................................................................................... 16
3.3.4 Battery operation .................................................................................................... 16
3.3.5 Manual bypass ........................................................................................................ 17

Table of Contents

Questions and Answers

  • W
    William SmithSep 13, 2025
    What to do if my LEGRAND UPS displays a DIESEL MODE?
    • W
      wwallSep 13, 2025
      If your LEGRAND Power Supply displays DIESEL MODE, it indicates that the auxiliary contact which activates the diesel generator connected to the UPS is closed, imposing this operating mode. Wait for the diesel generator to stop as soon as the mains voltage is restored. Also, check the connection of the auxiliary contact which signals the diesel generator start, to terminals XD1/XD2. If the alarm persists, contact our Technical Support Service.
  • J
    Julie BurnsAug 25, 2025
    What should I do if my LEGRAND Power Supply displays a BATTERY FAULT?
    • C
      Christopher MitchellAug 25, 2025
      If your LEGRAND Power Supply is showing a BATTERY FAULT, first check the battery itself. If the issue persists, try resetting the system. If the alarm still continues, contact our Technical Support Service.
  • S
    Scott CastroAug 25, 2025
    What to do if my LEGRAND Power Supply displays a SHORT CIRCUIT?
    • R
      Ryan MitchellAug 26, 2025
      If your LEGRAND Power Supply indicates a SHORT CIRCUIT, the issue might be related to the load. Check the loads connected to the UPS output. If the alarm persists, contact our Technical Support Service.
  • C
    Cory DaughertySep 23, 2025
    What to do if my LEGRAND Power Supply displays a BATT TEMPERATURE error?
    • S
      Samantha FullerSep 23, 2025
      If your LEGRAND Power Supply displays a BATT TEMPERATURE error, it indicates an anomalous temperature in the battery cabinet or a possible failure on the measuring circuit. Check the temperature on the batteries and remove the cause of the alarm, if any. If the alarm persists, contact our Technical Support Service.
  • M
    Maria PhelpsSep 14, 2025
    What to do if my LEGRAND Power Supply displays a DC FASTSHUTDOWN?
    • T
      Timothy BoydSep 14, 2025
      If your LEGRAND Power Supply shows a DC FASTSHUTDOWN, it may be due to a battery fault. Check the battery and reset the system. If the alarm persists, contact our Technical Support Service.
  • K
    Kenneth WolfeSep 23, 2025
    What to do if my LEGRAND UPS displays PAR LOST REDUND?
    • J
      Jessica HendrixSep 23, 2025
      If your LEGRAND Power Supply displays PAR LOST REDUND, it indicates that the total load is higher than the maximum expected value or a possible failure on the measuring circuit. Check the load fed by the system. If the alarm persists, contact our Technical Support Service.
  • K
    Karl HarrellSep 6, 2025
    What to do if my LEGRAND UPS displays a RETRANSFER BLOCK error?
    • E
      Elizabeth CastroSep 6, 2025
      If your LEGRAND Power Supply shows a RETRANSFER BLOCK error, it could be due to frequent changeovers caused by load in-rush currents or static switch problems. Reset the system and check the in-rush currents of the loads. If the alarm persists, contact our Technical Support Service.
  • J
    Jeremy JohnsonSep 7, 2025
    What does MBCB CLOSED mean on my LEGRAND UPS, and how to resolve it?
    • C
      Candice WilliamsSep 7, 2025
      If your LEGRAND Power Supply displays MBCB CLOSED, it means the manual bypass isolator is closed. Check the status of the manual bypass isolator and the functionality of the auxiliary contact of the isolator. If the alarm persists, contact our Technical Support Service.
  • L
    Larry PenningtonSep 23, 2025
    What does SSW BLOCKED mean on my LEGRAND Power Supply, and how can I fix it?
    • D
      diana72Sep 23, 2025
      If your LEGRAND Power Supply displays SSW BLOCKED, it could be due to loads failure or a possible UPS fault. Check the loads for possible failures and reset the system. If the alarm persists, contact our Technical Support Service.
  • P
    Paige BauerAug 31, 2025
    What to do if my LEGRAND UPS shows a BOOSTER STOPPED error?
    • R
      Randy RobinsonAug 31, 2025
      If your LEGRAND Power Supply is showing a BOOSTER STOPPED error, it may be due to instability of the AC line voltage or frequency, or a fault in the rectifier control circuit. Check the parameters of the AC line voltage and restart the device. If the alarm persists, contact our Technical Support Service.

Summary

1 SCOPE

Storing Documentation

Manual storage and accessibility instructions for technical documentation.

Further Information

Contacting the manufacturer for more details if the manual is insufficient.

2 Safety Rules and Warnings

Electric Shock Hazard

Safety instructions and precautions for electrical hazards.

Device Failure Hazard

Potential hazardous situations arising from UPS failure.

Potential Device Damage

Precautions to avoid electrostatic discharge during operations.

3 General UPS Description

3.1 UPS Typology

Description of the UPS's on-line, double conversion typology.

3.2 System Description

Overview of the UPS system components.

3.2.2 Inverter

3.2.3 Battery and Charger

3.2.4 Static Bypass

3.2.5 Manual Bypass

3.3 Operating Status

3.3.1 Normal Operation

UPS operates with all breakers closed except maintenance bypass.

3.3.2 Green Conversion

Battery disconnected; rectifier at reduced voltage.

3.3.3 Bypass Operation

3.3.4 Battery Operation

3.3.5 Manual Bypass

3.4 Control and Operation Devices

3.4.1 Isolators

Isolate power components from AC supply, battery, or load.

3.4.2 Emergency Power Off (EPO)

3.4.3 Normal;Bypass Selector

3.4.4 LCD Control Panel

4 Front Panel

4.1 Function Buttons

4.2 Mimic Panel LEDs

4.3 LEDs Bar

5 Handling the LCD Panel

5.1 Main Menus

Overview of the main LCD panel menus.

5.2 Measure Display

5.3 Basic Diagnostics

5.3.1 Display of Alarms History

How to view recorded alarms and their details.

5.3.2 Alarms and Operating Status

Alarm and Status Display Mode

How alarms are displayed and recorded in the system.

Alarms and Statuses Description

Reference to another section for detailed alarm and status descriptions.

6 Settings and Advanced Operations

Password-Protected Access

6.1 Setting Date and Time

6.2 Display Language Setting

6.3 New Battery Installation

6.4 Battery Configuration

6.5 Setting Modbus Parameters

6.6 UPS Test

6.7 Battery Test

6.8 System Reset

6.9 Alarms History Reset

Data Loss Warning

Warning about saving data before deleting alarms history.

7 System Information

7.1 Parallel Operation Information

7.1.1 UPS Position

Identifies UPS position in a parallel system.

7.1.2 Master;Slave Priority

Sets the Master/Slave role in parallel operation.

7.1.3 Communication Bus Monitoring

7.1.4 Parallel Type

7.1.5 Message Statistics

7.2 Service Information

8 Faults and Alarms

8.1 Operating Status Definition

8.2 Troubleshooting

LEGRAND UPS Specifications

General IconGeneral
BrandLEGRAND
ModelUPS
CategoryPower Supply
LanguageEnglish