Installation
a) Loosen the lock nuts on the feet by hand.
b) Adjust the feet untl the product stands level and balanced.
c) Tghten all lock nuts agan by hand.
Connect the product to a grounded outlet protected by a 16 A fuse. Our company
shall not be liable for any damages that will arise when the product is used without
grounding in accordance with the local regulations.
•Connectionmustcomplywithnationalregulations.
•Thewiringfortheelectricaloutletcircuitmustbesufficienttomeettheappliance
requirements. Use of a Groud Fault Circuit Interrupter (GFCI) is recommended.
•Powercableplugmustbewithineasyreachafterinstallation.
•Ifthecurrentvalueofthefuseorbreakerinthehouseislessthan16Amps,havea
qualified electrician install a 16 Amp fuse.
•The voltagespecifiedin the"Technicalspecifications"section must be equalto
your mains voltage.
B
DANGER!
Damaged power cables must be replaced by the
Authorised Service Agent.
As the colours of the wires in the mains lead of this appliance may not correspond
with the coloured markings identifying the terminals on your plug, proceed as
follows:
1 Connect the green - yellow or green (earth) wire to the terminal in the plug marked
‘E’ or with the symbol f or coloured green and yellow or green.
2 Connect the blue (neutral) wire to the terminal in the plug marked ‘N’ or coloured
black.
3 Connect the brown (live) wire to the terminal in the plug marked ‘L’ or coloured red.
With the alternative plugs a 16A fuse must be fitted either in the plug or adaptor or
in the main fuse box. If in doubt contact a qualified electrician.