6. MAINTENANCE
6.1 Introduction
This chapter contains the preventive maintenance schedule and the
applicable preventive maintenance procedures for the JUNO 150. It also
contains some basic corrective maintenance procedures.
6.2 Preventive Maintenance Schedule
The following table shows the preventive maintenance schedule for the
JUNO 150. Preventive maintenance must obey local regulations, if
applicable.
The frequencies of the tasks shown in the table are the minimum
frequencies recommended.
Maintenance Tasks Frequencies
Operating
Months
Operating
Years
Note
Clean the charging strips (page 65) 1
Clean the charging electrodes on the charge
unit (page 65)
1
Check the battery is charging (page 74) 1
Adjust the skirt height (page 66) 4 If the feed alley is not clean
enough
6.3 Preparation
6.3.1 Break or close the Power Circuit
To break the power circuit
1. Loosen the knob on the
battery stop (see figure on page 62) (1).
To close the power circuit
2. Fasten the knob on the battery stop.