7.3 Tests
7.3.1 Analyse the Reliability of a Route
1. Open the Lely Control app on the smartphone.
2. Stop the time path to take the JUNO 150 out of operation (page 5‑
15).
3.
In the main menu of the Lely Control app, select 'Routes' and push
[ ].
4.
Select 'Route analysis' and push [ ].
5.
Select 'Fail. problty' and push [ ].
Push [ ] or [ESC] to display routes that are not displayed.
6. If a route has a
failure probability of more than 2,
1. Find out the cause of the unreliability.
2. Modify the route.
7. Repeat steps 5 to 7.
8. If the route is still not reliable:
1. Delete the route.
2. Make a new route.
7.3.2 Test a Route
1. Put the route into a manual route.
2. Start the manual route (page 5‑
16).
3. Find the actions and action numbers on the display of the user
interface of the Lely Control app.
4. Make sure the route is correct.
7.3.3 Make sure the Battery is Loaded
1. Stop the time path to take the JUNO 150 out of operation (page 5‑15).
2.
In the main menu of the Lely Control app, select 'Work' and push
[ ].
3. Make sure the battery voltage is more than 12500 mV (fig. 1).
4.
If the voltage is less than 12500 mV:
1. Manually drive the JUNO 150 to the charging station.
2. Make sure the battery is charging (page 7‑4).
5. Charge the battery for one hour.
Test and Adjustment 7-3
5.4301.8501.0 A Lely Control