18
3.2.5 Induction valve
The liquid from the chemical inductor is delivered into the main tank by activating
the induction valve (5). The induction valve operates proportionally. It should
therefore only be activated insofar as there is always sufficient water remaining in
the chemical inductor for dissolving the medium.
(a) Induction ON
(b) Induction OFF
The valve settings are described as follows in plain text on the corresponding
instruction sign:
(a) INDUCTION ON
(b) INDUCTION OFF
b
a