EasyManua.ls Logo

LEMKEN Primus 45 - Agitating and Spraying Operations

LEMKEN Primus 45
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
4.4 Agitating
After filling with spray mixture, the
content of the main tank must be
agitated using transfer pumping.
Put the main switch in the “spray boom
OFF” position.
Put the filling valve or filling valves (1) in
the “suction from selection valve”
position.
Put selection valve (2) in the “main tank”
position
Put the distribution valve (3) in the
“spraying” position.
Put the internal cleaning valve (4) in the
“internal cleaning OFF” position.
Operate the tractor power takeoff or
hydraulic pump drive at 400 rpm to
maximum 540 rpm.
ATTENTION! Do not start spraying until
the content has been sufficiently agitated.
1
4
3
1
2

Related product manuals