38
4.8 Emptying the machine
ATTENTION!
Pesticides must not be left on the side of
paths or introduced into the sewer system
under any circumstances. Collected
pesticides must be taken to the specified
waste disposal location (ask for the
responsible place) or recycled (after
consultation with the respective pesticide
manufacturer).
If the machine is fitted with a pump out valve, pump out the contents of the tank.
Afterwards:
Place a collecting container under the outlet connection (1) of the main tank.
Unscrew the blind plug (2) of the outlet connection (1).
Open the drain valve (3).
Close the drain valve and refit the blind plug (2) after the emptying.
3
1
2

Related product manuals