4.3 Separate internal cleaning of the chemical inductor
Internal cleaning of the chemical inductor
(1) must be performed after the induction
of spray mixtures and also after a canister
rinsing. If the filling is done using a filling
hose, this is done already during the filling
of the main tank with clean water. If the
chemical inductor should be cleaned with
clean water from the clean water tank, all
valves must first be adjusted as follows
and the pump must not be switched on
until afterwards:
Put the selection valve (2) in the “clean
water tank” position (lever pointing up).
Put the filling valves (3) in the “suction
from selection valve” position.
Put the distribution valve (7) in the
“chemical inductor” position.
Put the induction valve (4) in the
“induction ON” position.