40
- Switch off the machine.
- Divide the collected liquid by the number of measurements = l/min per nozzle
(e.g. 4.5 l: 3 measurements = 1.5 l/min/nozzle).
- If individual nozzles show deviations from each other, the nozzles must be
checked on a tester and/or replaced.
The spraying pressure determined during the volumetric measurement is used as
the reference point for the assessment and monitoring of the droplet spectrum
and for adjustment of the spraying pressure on the on-board computer or
operating terminal in the "MAN" position.
Calibration:
The total machine output should always be the multiple of the individual nozzle
output.
Example:
Individual nozzle output 1.5 l/min/nozzle x 48 nozzles (24 m boom) = 72 l/min.
If the l/min value of the on-board computer or operating terminal deviates from the
multiple of the individual nozzle output, the control unit must be recalibrated.