icomfort™ Communicating Control System / Page 9
FEATURES
INSTALLER SETUP
System Devices (Continued)
Furnace:
Equipment Name
Heating Airow Control Type - Selections available
if Discharge Air Temperature Sensor is installed
(Fixed cfm, xed Discharge Air Temperature)
With Discharge Air Temperature:
Low Heating Discharge Air Temperature -
Available if Discharge Air Temperature Sensor is
installed (110 to 140°F in 5°F increments, default
is 120°F)
High Heating Discharge Air Temperature -
Available if Discharge Air Temperature Sensor is
installed (120 to 150°F in 5°F increments, default
is 135°F)
With Fixed cfm:
Low Heating Airow (325 to 1280 in 25 cfm
increments
High Heating Airow (300 to 1805 in 25 cfm
increments
Low Cooling Airow (300 to 1390 in 25 cfm
increments
High Cooling Airow (300 to 2190 in 25 cfm
increments
Airow Prole Cooling:
A. On (50% for 30 sec., 82% for 7.5 min.); Off (50%
for 30 sec.)
B. On (82% for 7.5 min.); Off (No delays)
C. No delays; Off (45 sec. delay)
D. No delays
Low HP Airow (300 to 1400 cfm in 25 cfm
increments)
High HP Airow (300 to 1400 cfm in 25 cfm
increments)
Continuous Indoor Blower Airow (300 to 1400 in 25
cfm increments)
Humidication Airow (300 to 1400 cfm in 25 cfm
increments, default is 500 cfm)
Dehumidication Airow (60 to 80% RH in 1%
increments)
Heating Indoor Blower Off Delay (60 to 80 sec. in 10
sec. increments default is 90 sec.)
Heating Indoor Blower On Delay (15 to 45 sec. in 5
sec. increments, default is 45 sec.)
Cooling Indoor Blower Off Delay (0 to 30 sec. in 2
sec. increments, default is 0 sec.)
Cooling Indoor Blower On Delay (0 to 10 sec. in 5
sec. increments, default is 2 sec.)
HP Indoor Blower Off Delay (0 to 60 sec. in 5 sec.
increments, default is 45 sec.)
HP Indoor Blower On Delay (0 to 30 sec. in 5 sec.
increments, default is 0 sec.)
All furnace default airow settings are dependent on
furnace capacity.
NOTE - Humidication and Dehumication Airow
settings are only viewable if those non-communicating
products are added during setup.
Air Handler
Equipment Name
Electric Heating Airow (1560 to 2150 cfm in 5 cfm
increments)
Low Cooling Airow (450 to 2150 cfm in 5 cfm
increments)
High Cooling Airow (450 to 2150 cfm in 5 cfm
increments)
Airow Prole Cooling:
1. No Delays
2. On (No delays); Off (45 sec. delay)
3. On (82% for 7.5 min.); Off (No delays)
4. On (50% for 30 sec., 82% for 7.5 min.); Off (50%
for 30 sec.)
Low HP Airow (450 to 2150 cfm in 5 cfm
increments)
High HP Airow (450 to 2150 cfm in 5 cfm
increments)
Continuous Indoor Blower Airow (450 to 2150 in 10
cfm increments)
Humidication Airow (450 to 2150 cfm in 5 cfm
increments)
Dehumidication Airow % (60 to 80% RH in 1%
increments)
Heating Indoor Blower OFF Delay (0 to 10 sec. in 1
sec. increments, default is 10 sec.)
Heating Indoor Blower ON Delay (0 to 5 sec. in 1
sec. increments, default is 0 sec.)
Cooling Indoor Blower OFF Delay (0 to 30 sec. in 2
sec. increments, default is 0 sec.)
Cooling Indoor Blower ON Delay (0 to 10 sec. in 1
sec. increments, default is 2 sec.)
HP Indoor Blower OFF Delay (0 to 60 sec. in 5 sec.
increments, default is 45 sec.)
HP Indoor Blower ON Delay (0 to 30 sec. in 5 sec.
increments, default is 0 sec.)
All air handler default airow settings are dependent on
furnace capacity.

Other manuals for Lennox icomfort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox icomfort and is the answer not in the manual?

Lennox icomfort Specifications

General IconGeneral
DisplayColor touchscreen
ConnectivityWi-Fi
CompatibilityLennox HVAC systems
Energy ReportsYes
Voice ControlAmazon Alexa, Google Assistant
Programming7-day programmable
Humidity ControlYes
Smart Featuresgeofencing
Featuresair quality monitoring

Related product manuals