icomfort™ Communicating Control System / Page 10
FEATURES
INSTALLER SETTINGS
Thermostat:
Temp. Reading Calibration (-5 to 5°F, default is 0°F)
Humidity Reading Calibration (-10 to 1F, default is F)
System
Equipment Name
Filter 1 Timer Selection (Calendar or Run Time)
Filter 2 Timer Selection (Calendar or Run Time)
UV Bulb Timer Selection (Calendar or Run Time)
Humidier Pad Timer Selection (Calendar or Run Time)
PureAir Timer Selection (Calendar or Run Time)
Smooth Setback Recovery (Enabled/Disabled)
Electric Heat Control Mode (Standard/EvenHeat)
Gas Heat Control Mode (Staged/Modulating)
Auto-Changeover Temp. Deadband (3 to 9°F,
default is 5°F)
Max. Heat Setpoint (40 to 90°F, default is 90°F)
Min. Cool Setpoint (60 to 99°F, default is 60°F)
Heat Cool Stages Locked In (Enabled/Disabled)
1st Stage Differential (0.5 to 3°F, default is 0.5°F)
2nd Stage Differential (0.5 to 8°F, default is 1.5°F)
3rd Stage Differential (0.5 to 8°F, default is 2°F)
4th Stage Differential (0.5 to 8°F, default is 2.5°F)
5th Stage Differential (0.5 to 8°F, default is 3°F)
6th Stage Differential (0.5 to 8°F, default is 3.5°F)
Staged Delay Timers (Enabled/Disabled)
2nd through 6th Stage Delays (5 to 120 min. in 5
min. increments, default is 20 min.)
Locked in 2nd Stage HP by Outdoor Temp (off,
40°F, 45°F, 50°F, 55°F)
Balance Point Control (enabled/disabled)
Defrost Target Discharge Temp (50 to 60°F in 1°F
increments, default is 55°F)
EvenHeater
®
Discharge Temp (80 to 130°F in 1°F
increments, default is 85°F)
Dehumidication Control Mode (Display Ony, Basic,
Precision)
Humidication Control Mode (Display Only,
Dewpoint Control)
OK/Humid Boundary (45 to 60°F in 1°F increments,
default is 50°F
NOTE - Depending on type of system (conventional
heating/cooling or heat pump system) not all system
settings will be displayed.
TESTS
A variety of system tests can be performed by the
installer. Press the tests tab, then press start to begin
system testing.
setup tests equipment HELP
selected tests
select tests to run
select
TEST ALL
Blower
HP Heat − 1st
Stage
HP Heat − 2nd
Stage
Defrost Now
Cooling − 1st
Stage
Cooling − 2nd
Stage
skip tests
press start button below to begin system testing
start
alerts diagnostics EXIT
TEST ALL is the default.
You can also test equipment individually. Use up / down
arrow buttons to select device.
Then press select, then start on the next screen to test
all or individual equipment.
setup tests equipment HELP
selected tests
TEST ALL
select tests to run
select
TEST ALL
Blower
HP Heat − 1st
Stage
HP Heat − 2nd
Stage
Defrost Now
Cooling − 1st
Stage
Cooling − 2nd
Stage
startremove
alerts diagnostics EXIT
The remove button allows to you remove individual
equipment from the TEST ALL list if you only want to test
certain equipment. Press the start button to begin testing.
CURRENT TEST: Blower
Check Blower Operation
next
cancel
When a test is running, a status screen will show
which test is being run. A Testing Process is Finished
conrmation screen will appear when testing is complete.
NOTE - The tests feature is not available until after setup
has been completed at least once.

Other manuals for Lennox icomfort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox icomfort and is the answer not in the manual?

Lennox icomfort Specifications

General IconGeneral
DisplayColor touchscreen
ConnectivityWi-Fi
CompatibilityLennox HVAC systems
Energy ReportsYes
Voice ControlAmazon Alexa, Google Assistant
Programming7-day programmable
Humidity ControlYes
Smart Featuresgeofencing
Featuresair quality monitoring

Related product manuals