EasyManua.ls Logo

Lennox MPD40RNM

Lennox MPD40RNM
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MODELS
MPD Direct-Vent
Gas Fireplaces
CARE AND OPERATION INSTRUCTIONS
P/N 506017-06 Rev. A 08/2012
This manual is one of a set of two supporting this product.
Refer to P/N 506015-07 for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-44.
OTL Report No. 116-F-13g-5
US
Portland
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
DON’T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
Wait...
ƒ
F
ƒ
R
ƒ
E
ƒ
E
ƒ
ƒ
See Page 2 For Details
ƒ
SAFETY
GU ARD
PROTECTS AGAINST BURNS
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
[EN FRANÇAIS] L’information de sûreté importante . . . . . . . . . . . . . . . 34
Apposition des mises en garde relatives à la sécurité d’utilisation . . . . 5
[EN ESPAÑOL] Información importante de seguridad . . . . . . . . . . . . . . 3–4
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
WARNING
/
AVERTISSEMENT
/
AVISO
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
s(/4',!337),,#!53%
"52.3
s$/./44/5#(',!33
5.4),#//,%$
s.%6%2!,,/7#(),$2%.
4/4/5#(',!33
s5.%352&!#%6)42»%#(!5$%
0%54#!53%2$%3"2Ä,52%3
s,!)33%22%&2/)$)2,!352&!#%
6)42»%!6!.4$g94/5#(%2
s.%0%2-%44%:*!-!)3Ã5.%.&!.4
$%4/5#(%2,!352&!#%6)42»%
s%,6)$2)/#!,)%.4%
#!53!2¬15%-!$52!3
s534%$$%"%.5.#!
4/#!2%,6)$2)/#!,)%.4%
s,/3.)¶/3$%"%..5.#!
4/#!2%,6)$2)/
$ONOTSTOREORUSEGASOLINEOROTHERFLAMMABLE
vapors and liquids in the vicinity of this or any other
appliance.
7(!44/$/)&9/53-%,,'!3
s$ONOTTry to light any appliance.
s$ONOTTOUCHANYELECTRICALSWITCHDONOTUSEANY
phone in your building.
s)MMEDIATELYCALLYOURGASSUPPLIERFROMA
neighbor’SPHONE&OLLOWTHEGASSUPPLIER’s
instructions.
s)FYOUCANNOTREACHYOURGASSUPPLIERCALLTHEFIRE
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
15%&!)2%3)6/533%.4%:5.%/$%52$%'!:
s.EPASTENTERDALLUMERDAPPAREIL
s.ETOUCHEZÜAUCANINTERRUPTEUr. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
s!PPELEZIMM£DIATEMENTVOTREFOURNISSEURDEGAZDEPUIS
un voisin. Suivez les instructions du fournisseur.
s3IVOUSNEPOUVEZREJOINDRELEFOURNISSEURDEGAZ
appelez le service des incindies.
- ,’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
MILLIVOLT: ELECTRONIC:
MPDT33RNM
MPDT33RPM
MPDR33RNM
MPDR33RPM
MPD35CNM
MPD35RNM
MPD35RPM
MPD40CNM
MPD40RNM
MPD40RPM
MPD45RNM
MPD45RPM
MPDT33RNE
MPDR33RNE
MPD35CNE
MPD35RNE
MPD40CNE
MPD40RNE
MPD45RNE

Other manuals for Lennox MPD40RNM

Question and Answer IconNeed help?

Do you have a question about the Lennox MPD40RNM and is the answer not in the manual?

Lennox MPD40RNM Specifications

General IconGeneral
CategoryIndoor Fireplace
ModelMPD40RNM
Vent TypeDirect Vent
Control TypeRemote Control
TypeDirect Vent
Fuel TypeNatural Gas
Ignition TypeElectronic

Summary

Safety and Your Fireplace

Important Safety Information

Crucial safety guidelines for operating the fireplace safely and preventing hazards.

Free Safety Guard Offer

Information on how to obtain a free safety guard to prevent burns from hot surfaces.

Attaching Safety-in-Operation Warnings

Instructions on applying safety labels to warn users about hot surfaces and operation hazards.

Safety Label Diagrams

Visual representation of safety labels and their placement on the appliance.

General Information

BTU Input

Specifies the heat output (BTU/HR) for different gas types and models.

Gas Pressure Requirements

Outlines the required inlet and manifold gas pressure for proper appliance function.

Burn-in Period

Explains the initial curing process, potential odors, and initial cleaning recommendations.

Appliance Installation, Service, and Maintenance Notices

Appliance Operation Notices

Warranty Information

Operation and Care of Your Appliance

Gas ControlsControl Compartment Access

Instructions for accessing and operating the gas controls and compartment.

Variable Flame Height Adjustment

How to adjust the flame height using the gas control valve for desired output.

Millivolt Appliance Operation

Specific operation details for millivolt models, including lighting and controls.

Electronic Appliance Operation

Specific operation details for electronic models, including lighting and controls.

Maintenance

Cleaning Glass

Procedures and precautions for cleaning the fireplace glass safely and effectively.

Inspect Glass Gasket

Guidance on visually inspecting the glass gasket for proper seal and condition.

Clean Control Compartment

Instructions for cleaning the control compartment to ensure proper function and safety.

Clean Logs and Burner

How to clean the logs and burner assembly for optimal performance and appearance.

Replacing Logs

Information on replacing logs and ordering correct parts.

Reinstall Embers and Logs

Instructions for correctly placing embers and logs for proper flame pattern.

Inspect Wiring

How to inspect wiring connections for safety and proper operation.

Small Area Paint Touch-up

Guidance on using touch-up paint for minor cosmetic repairs on the appliance.

Front Glass Enclosure Panel, Removal and Installation

Removing Glass Enclosure Panels

Step-by-step guide on safely removing the front glass enclosure panel.

Reinstalling the Glass Enclosure Panel

Instructions for correctly reinstalling the front glass enclosure panel.

Install Volcanic Stone, Glowing Embers, and Logs

MPD33 Log Placement

Specific placement instructions for the log set for MPD33 models.

MPD35 Log Placement

Specific placement instructions for the log set for MPD35 models.

MPD40 and MPD45 Log Placement

Specific placement instructions for the log set for MPD40 and MPD45 models.

Burner Adjustments

Flame Appearance and Sooting

How to achieve proper flame appearance and diagnose/fix sooting issues.

Air Shutter Adjustment Guidelines

Procedures for adjusting the air shutter for optimal flame and combustion.

Burner Flame Adjustments

Detailed steps for adjusting the burner flame for correct appearance and performance.

Millivolt Appliance Checkout

Procedure to check the pilot and burner operation on millivolt systems.

Electronic Appliance Checkout

Procedure to check the pilot and burner operation on electronic systems.

Wiring Diagrams

Ordering Replacement Parts

Product Reference Information

Accessory Components

Remote Control Systems

Details on available economy, standard, and deluxe remote control systems.

Digital Wall Thermostat

Information on the wall thermostat kit for temperature control.

Touch-Up Paint Kit

Kit for repairing minor scratches and discoloration on the appliance.

ONOFF Wall Switch Kit

Optional wall switch for controlling fireplace burner operation.

Unit-Mountable ONOFF Rocker Switch Kit

Optional rocker switch for millivolt systems, mounts directly to gas valve.

Forced Air Blower Kit

Various blower kits for forced-air circulation, available in single and variable speed.

Assembled Louver Kits

Louver kits to replace standard radiant or optional louvered panels.

Screen Panel Kits

Screen panels for protection from hot glass surfaces.

Termination Guard Kits

Guards to cover vent termination and minimize exposure to hot surfaces.

Firebox Liner Kits

Ceramic liner kits with brick-like features for the firebox interior.

Style View Doors

Decorative doors available in different pane designs for enhanced aesthetics.

Arch Design Kits

Door kits featuring an arched pane design for the fireplace.

Square Pane Design Kits

Door kits featuring a square pane design for the fireplace.

Grille Kits

Sunrise design grilles available in black or satin pewter for replacing standard panels.

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Schedule of annual maintenance tasks performed by a qualified technician.

Periodically (After the Burning Season)

Schedule of periodic maintenance tasks performed by the homeowner.

Lighting Instructions - Millivolt Gas Valve

To Turn Off Gas To Appliance

Steps to safely shut off the gas supply to the appliance.

Lighting Instructions-Electronic

To Turn Off Gas To Appliance

Steps to safely shut off the gas supply to the appliance for electronic models.

Troubleshooting Guide: Millivolt Gas Control System

Troubleshooting Guide: Electronic Gas Control System

Replacement Parts List

Related product manuals