Table 59. Menu Interface (Level 1 - SETTINGS)
NOTE: AVAILABLE MENU OPTIONS ARE DEPENDENT ON HARDWARE CONFIGURATION. USE THE ADJUST AND SET VALUES ARROWS
TO SCROLL UP OR DOWN FOR SELECTION OPTIONS.
Level 2 Level 7Level 6Level 5Level 4Level 3
RTU OPTION
DEHUMIDIFIER
MODE
= BLOWER,
OCCUPIED
= LOCAL SENSOR,
NETWORK SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= NO CONDITIONS
= LOCAL SENSOR
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= REPORT RH ONLY = LOCAL SENSOR OR NETWORK SENSOR
= DISABLED
= BLWR, OCC,
PREV COOL
= LOCAL SENSOR
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
= PREVIOUS
COOLING
= LOCAL SENSOR,
OR NETWORK
SENSOR
DEHUMIDIFIER DEHUMID SETPOINT = X.XX %
DEHUMIDIFIER DEHUMID DEADBAND = X.X %
= REHEAT DI4
EDIT PARAMETER ENTER DATA ID =
INSTALL
NEW UNIT SETUP
SEE TABLE 57 ON PAGE 98 FOR SETUP PROMPTS FOR NEW SETUP. (THIS IS THE SAME AS
SETUP > INSTALL DEHUMIDIFIER MODE PORTION OF THE WIZARD.)
INSTALL NEW M3
CLEAR ALL CONFIG=YES OR NO. IF YES IS SELECTED. ARE YOU SURE?=YES OR NO. SEE
TABLE 57 ON PAGE 98 FOR SETUP PROMPTS FOR NEW M3 UNIT CONTROLLER.
NOTE: PARAMETERS AVAILABLE ARE DEPENDENT ON MODEL NUMBER AND CONFIGURATION ID 1 AND 2 SETTINGS. IN ORDER FOR
ANY CHANGE TO THE SYSTEM TO TAKE AFFECT, BACK COMPLETELY OUT OF THE CURRENT LOCATION TO THE MAIN MENU OR
STATUS SCREEN.
GENERAL
LANGUAGE = ENGLISH, FRANCAIS OR ESPANOL
DATE/TIME
DAY, MONTH, YEAR HOURS, MINUTES AND SECONDS
NOTE: HOURS IN 24 HOUR CLOCK FORMAT (MILITARY)
DISPLAY UNITS F/C = FAHRENHEIT OR CELSIUS
RTU DESCRIPTION ENTER A 18 POSITION ALPHA / NUMERIC NAME
CATALOG NUMBER = LOCATED ON UNIT NAMEPLATE.
MODEL NUMBER = LOCATED ON UNIT NAMEPLATE.
SERIAL NUMBER = LOCATED ON UNIT NAMEPLATE.
CONFIGURATION ID
1
= WHITE STICKER TITLED “ORIGINAL FACTORY UNIT CONFIGURATION” LOCATED ON THE
RIGHT SIDE OF THE CONTROL BOX NEAR THE M3 CONTROLLER.
CONFIGURATION ID
2
NOTE: PARAMETERS AVAILABLE ARE DEPENDENT ON MODEL NUMBER AND CONFIGURATION ID 1 AND 2 SETTINGS. IN ORDER FOR
ANY CHANGE TO THE SYSTEM TO TAKE AFFECT, BACK COMPLETELY OUT OF THE CURRENT LOCATION TO THE MAIN MENU OR
STATUS SCREEN.