IMPORTANT
Supply air VFD motor rotation is controlled indepen
dently from scroll compressor rotation. See Cooling
Start-Up section for correct compressor rotation.
Compressor damage due to improper rotation is the
responsibility of the installer.
Table of Contents
Dimensions Page 2.................................
Parts Arrangements Page 5.........................
Shipping and Packing List Page 8....................
General Page 8....................................
Safety Page 8.....................................
Unit Support Page 9................................
Duct Connection Page 10............................
Rigging Unit For Lifting Page 10.......................
Condensate Drains Page 10..........................
Gas Piping Page 11.................................
Pressure Test Gas Piping Page 11.....................
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
INSTALLATION
INSTRUCTIONS
SGH/SCH036 (3 TON)
SGH/SCH060 (5 TON)
SGH/SCH120 (10 TON)
SGH/SCH240 (20 TON)
ROOFTOP UNITS
507964-01
9/2019
Supersedes 507364-02
High Altitude Derate Page 12.........................
Optional Outdoor Air Hood Page 13....................
Electrical Connections Page 15.......................
Blower Operation and Adjustments Page 17............
Cooling Start-Up Page 29............................
Cooling Operation and Adjustments Page 31............
Gas Heat Start-Up Page 41...........................
Electric Heat Start-Up Page 43........................
Heating Operation and Adjustments Page 43............
MSAV
t Unit Start-Up Page 45........................
MSAV
t Operation Page 46..........................
Direct Drive Start-Up Page 47.........................
Hot Gas Reheat Startup Page 49......................
Economizer Start-Up Page 53.........................
Service Page 55....................................
Factory Control Parameter Settings Page 58............
Start-Up Report Page 60.............................
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person
al injury or loss of life. Installation and service must
be performed by a licensed professional HVAC in
staller or equivalent, service agency, or the gas sup
plier
WHAT TO DO IF YOU SMELL GAS:
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
WARNING
Do not store or use gasoline or
other flammable vapors and liq
uids in the vicinity of this or any
other appliance.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
S Do not try to light any appliance.
S Extinguish any open flame.
S Do not touch any electrical switch; do not
use any phone in your building.
S Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli
er's instructions.
S If you cannot reach your gas supplier, call
the fire department.
S Leave the building immediately.
Question and Answer IconNeed help?

Do you have a question about the Lennox SCH240 and is the answer not in the manual?

Lennox SCH240 Specifications

General IconGeneral
BrandLennox
ModelSCH240
CategoryAir Conditioner
LanguageEnglish

Summary

Shipping, Safety, and General Information

Safety Warnings

Critical warnings about electrical hazards, refrigerant handling, and installation safety.

Gas Piping and Testing Procedures

Connecting Gas Supply Piping

Guidelines for connecting gas supply piping, including size and pressure.

Pressure Testing Gas Lines

Procedure for pressure testing gas lines and gas valve precautions.

Electrical Connections

Power Supply and Control Wiring

Instructions for connecting power supply and control wiring, including thermostat.

Blower Operation and Adjustments

Blower Drive Operation and Service Access

Procedures for blower operation, adjustments, and accessing the assembly.

Cooling Start-Up Procedures

Electrical Safety Warning

Warning about electric shock hazard during cooling start-up.

Unit Start-Up Sequence

Step-by-step procedure for starting the unit for cooling operation.

Three-Phase Compressor Phasing

Ensuring correct compressor and blower rotation for three-phase power.

Cooling Operation and Adjustments

Refrigerant Charge and Check Procedure

Procedures for checking and adjusting the refrigerant charge.

Heating Operation and Adjustments

MSAV Unit Start-Up Procedures

Hot Gas Reheat Start-Up and Operation

Unit Service and Maintenance

Unit Start-Up Report