EasyManua.ls Logo

Lennox XC21 Series

Lennox XC21 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2
XC21
Model Number Identification
C 21
XXX
Unit Type
C = Air Conditioner
Series
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Minor Revision Number
230
Voltage
230 = 208/230V−1ph−60hz
Refrigerant Type
X = R−410A
X
04
Typical Serial Number Identification
8 09 C
Year Code
08 = 2008
09 = 2009
10 = 2010
Month Code
A = January
B = February
C = March
05716
5 (or 6) Digit Unique
Number
Location Code
19 = Saltillo, Mexico
20 = Gainesville, FL
56 = Stuttgart, AR
58 = Marshalltown, IA
5
Specifications
Model Number
Unit Outdoor Fan
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter − inches.
XC21−024−230−04 69 12 lbs. 0 oz. 3 26.0
XC21−024−230−05 69 11 lbs. 12 oz. 5 26.1
XC21−024−230−06 69 11 lbs. 12 oz. 5 26.1
XC21−036−230−04 71 12 lbs. 5 oz. 3 26.0
XC21−036−230−05 71 12 lbs. 5 oz. 5 26.1
XC21−036−230−06 71 12 lbs. 5 oz. 5 26.1
XC21−048−230−04 73 13 lbs. 0 oz. 3 26.1
XC21−048−230−05 73 13 lbs. 0 oz. 5 26.1
XC21−048−230−06 73 13 lbs. 0 oz. 5 26.1
XC21−060−230−04 73 13 lbs. 0 oz. 3 26.0
XC21−060−230−05 73 13 lbs. 0 oz. 5 26.1
XC21−060−230−06 73 13 lbs. 0 oz. 5 26.1
1
Tested according to AHRI Standard 270−2008 test conditions.
2
Refrigerant charge sufficient for 15 feet length of refrigerant lines.

Related product manuals