2.Toreinstalltherackhandles,alignthescrewholesintherackhandlewiththecorrespondingholesinthe
chassis.Installthescrewstosecuretherackhandleoneachsideoftheserver.
Figure46.Installingtherackhandles
Removingandreinstallingthecoolingshroud
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Readthisfirst:safety
information”onpagevand“Guidelines”onpage73.
Toaccesssomeoftheservercomponentsonthesystemboard,removethecoolingshroudfirst.Toensure
propercoolingandairflow,reinstallthecoolingshroudbeforeturningontheserver.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Toremoveandreinstallthecoolingshroud,dothefollowing:
1.Removeallexternalmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,
disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedto
theserver.
2.Prepareyourserver.See“Removingorextendingtheserverfromtherackcabinet”onpage75.
3.Removetheservercover.See“Removingtheservercover”onpage75.
4.RemovetheThinkServerRAIDSuperCapacitorModuleifoneisinstalledonthecoolingshroud.See
“RemovingtheThinkServerRAIDSuperCapacitorModule”onpage151.
78ThinkServerRD650UserGuideandHardwareMaintenanceManual