Before installing the hot -swap power supply, 
1.  Watch the procedure. A video of this procedure is available from the following links: 
•  Youtube: 
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Dy5N2dPXFx5Pht-FljAi6S
•  Youku: https://list.youku.com/albumlist/show/id_51977169
2.  Touch the static-protective package that contains the component to any unpainted metal surface on the 
server; then, remove it from the package and place it on a static-protective surface.
To install the hot-swap power supply, complete the following steps:
Step 1.  If there is a power-supply-bay filler installed, remove it. 
Important: To ensure proper cooling during normal server operation, both of the power supply 
bays must be occupied. This means that each bay must have a power supply installed; or one has 
a power supply installed and the other has a power-supply filler installed.
Figure 51. Hot-swap power supply filler removal
Step 2.  Note the orientation of the hot-swap power supply, and then slide it into the chassis until it snaps 
into position. 