Troubleshooting and fault elimination
7-3
BA2131EN
POW1 = 007E
hex
selection
1
PIW1 =
xxxx xxxx x011 0001
bin
(ready for switch on)?
PIW1 =
xxxx xxxx x011 0111
bin
(operation enabled)?
no
yes
POW1=0007F
hex
selection
OK
Enable controller
(terminal28, C40)
For 821X/8200 vector/822Xwith
L-C0106 <> 0
setpoint selection via PAW2
no
yes
It is possible to select setpoints
or other control signals