3-22
8200 motec/starttec en 12/03
X3/ Designation Function :Level
PES Additional HF screen termination
A T/R(A) RS485 data line A
B T/R(B) RS485 data line B
CN CNTR see PROFIBUS-DP standard
1)
When sending data:
CNTR = HIGH
(+5 V, reference: GND3)
VP see PROFIBUS-DP standard
1)
+5 V (reference: GND3)
40 GND3 Reference potential for PROFIBUS-DP network
1)
7 GND1 Reference potential for X3/20
39 GND2
Reference potential for contr. inhibit (CINH) on X3/28
28 CINH Controller inhibit • Start = HIGH (+12 V ... +30 V)
• Stop = LOW (0 … +3 V)
20 DC voltage source for internal controller inhibit +20 V (reference: GND1)
(CINH) power supply
59 External DC power supply for function module U(ext.) = +24 VDC ±10%
(reference: GND1)
Automation
Fieldbus function modules
Terminal assignment
The PROFIBUS-DP function module is a slave connection
module with the PROFIBUS-DP communication profile.
It is used for networking between the host and
8200 motec/starttec.
Controller inhibit (CINH) power supply via internal
voltage source (X3/20)
Minimum wiring required for operation
Controller inhibit (CINH) power supply via external
voltage source
Function module and controller inhibit
(CINH) power supply via external voltage source
PROFIBUS-DP
PROFIBUS DP – can be used in the 8200 motec Order no. E82ZAFPC001
– can be used in the starttec (always in conjunction with
the support frame for function modules E71ZJ001)
1)
e.g. connection of a repeater