Configuration
UOMu_^MVMO 7-9
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoSelectionLenze
Name
C117
¿
Function relay
K2
822X/824X
-0- -0- Ready for operation
-1- TRIP fault message
-2- Motor is running
-3- Motor is running / CW rotation
-4- Motor is running / CCW rotation
-5- Field frequency f
d
=0
-6- f
dSet
reached
-7- Q
min
reached
-8- I
max
reached
-9- Overtemperature (
J
max
-10°C)
-10- TRIP or Q
min
or IMP
-11- PTC warning
C119
¿
Function PTC
822X/824X
-0- -0- PTC input inactive
-1- PTC input active,
TRIP and I MP (pulse inhibit) are set
-2- PTC input active, warning
C120
I
2
¡ t s witch off
822X/824X 0 0 {1 %} 100
C125
¿*
LECOM baud
rate
-0- -0- 9600 baud
-1- 4800 baud
-2- 2400 baud
-3- 1200 baud
-4- 19200 baud
Only for
LECOM
applications
C142
¿
Start c ondition -1- -0- Automatic start inhibited, flying-restart
circuit inactive
-1- Automatic start, if term. 28 HIGH,
flying-restart circuit not active
-2- Automatic start inhibited, flying-restart
circuit active
-3- Automatic start, if term. 28 HIGH,
flying-restart circuit active