Basis of the data
Voltage Frequency
AC mains connection [V
rate
d
]
3/PE AC 320 V − 0 % ... 440 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
DC−mains connection
(alternatively)
[U
DC
] DC 450 V − 0 % ... 620 V + 0 % ˘
Output voltage
With mains choke 3 ~ 0 approx. 94 % V
rated
˘
Without mains choke 3 ~ 0 ... U
N
˘
9300 Mains current
1)
Typical motor power Output power Power loss
With
mains choke
Without
mains choke
ASM
(4−pole)
8 kHz
2)
U, V, W +U
G
, −U
G
3)
Type I
r
[A] I
r
[A] P
r
[kW] P
r
[hp] S
r8
[kVA] P
DC
[kW] P
V
[W]
EVS9321−xx 1.5 2.1 0.37 0.5 1.0 2.0 100
EVS9322−xx 2.5 3.5 0.75 1.0 1.7 0.75 110
EVS9323−xx 3.9 5.5 1.5 2.0 2.7 2.2 140
EVS9324−xx 7.0 ˘ 3.0 4.0 4.8 0.75 200
EVS9325−xx 12.0 16.8 5.5 7.5 9.0 0 260
EVS9326−xx 20.5 ˘ 11.0 15.0 16.3 0 390
EVS9327−xx 27.0 43.5 15.0 20.0 22.2 10 430
EVS9328−xx 44.0 ˘ 22.0 30.0 32.6 4 640
EVS9329−xx 53.0 ˘ 30.0 40.0 40.9 0 810
EVS9330−xx 78.0 ˘ 45.0 60.0 61.6 5 1100
EVS9331−xx 100 ˘ 55.0 75.0 76.2 0 1470
EVS9332−xx 135 ˘ 75.0 100 100.5 0 1960