Electrical installation
Wiring of the control connections
Important notes
5
199
EDKVS9332X DE/EN/FR 8.0
Terminal data
Stop!
ƒ Connect or disconnect the terminal strips only if the controller is
disconnected from the mains!
ƒ Wire the terminal strips before connecting them!
ƒ Unused terminal strips must also be plugged on to protect the contacts.
Cable type Wire end ferrule Maximum cable
cross−section
Tightening torque Stripping
length
Rigid 2.5 mm
2
(AWG 14)
0.5 ... 0.6 Nm
(4.4 ... 5.3 lb−in)
5 mm
Flexible
Without wire end
ferrule
2.5 mm
2
(AWG 14)
Flexible
Wire end ferrule
without plastic sleeve
2.5 mm
2
(AWG 14)
Flexible
Wire end ferrule with
plastic sleeve
2.5 mm
2
(AWG 14)