13 Parameter reference
13.4 Table of attributes
72
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Table of attributes
Code Name Index Data Access
dec hex DS DA DT Factor R W CINH
C13231
Service code 11344 0x2C50 A 32 UNSIGNED_64 
C13489
Service code 11086 0x2B4E A 1 UNSIGNED_8 1 
C13531
Service code 11044 0x2B24 A 32 UNSIGNED_64 
C13789
Service code 10786 0x2A22 A 1 UNSIGNED_8 1 
C13850
All words from drive to master 10725 0x29E5 A 32 UNSIGNED_16 1
C13851
All words from master to drive 10724 0x29E4 A 32 UNSIGNED_16 1
C13852
All words to the basic device 10723 0x29E3 A 32 UNSIGNED_16 1
C13853
All words to the basic device 10722 0x29E2 A 32 UNSIGNED_16 1
C13854
Length of ports mapped into receive
PDO
10721 0x29E1 A 1 UNSIGNED_8 1
C13855
Length of ports mapped into send PDO 10720 0x29E0 A 1 UNSIGNED_8 1
C13860
Settings 10715 0x29DB A 2 UNSIGNED_8 1
C13861
Bus status 10714 0x29DA E 1 BITFIELD_16
C13862
Counter 10713 0x29D9 A 4 UNSIGNED_16 1
C13863
Active baud rate 10712 0x29D8 E 1 UNSIGNED_8 1
C13880
Monitoring Reaction 10695 0x29C7 A 1 UNSIGNED_8 1 
C13881
Response time if the INTERBUS
communication is interrupted
10694 0x29C6 E 1 UNSIGNED_16 1 
C13885
Clear process data 10690 0x29C2 E 1 UNSIGNED_8 1 
C13892
PCP data length 10683 0x29BB E 1 UNSIGNED_8 1 
C13893
Process data length 10682 0x29BA E 1 UNSIGNED_8 1 
C13894
Baud rate 10681 0x29B9 E 1 UNSIGNED_8 1 
C13900
Firmware product type 10675 0x29B3 E 1 VISIBLE_STRING
C13901
Firmware compilation date 10674 0x29B2 E 1 VISIBLE_STRING
C13902
Firmware version 10673 0x29B1 E 1 VISIBLE_STRING
C13920
Display of DIP switch position 10655 0x299F E 1 BITFIELD_8
C14231
Service code 10344 0x2868 A 32 UNSIGNED_64 
C14489
Service code 10086 0x2766 A 1 UNSIGNED_8 1 
C14531
Service code 10044 0x273C A 32 UNSIGNED_64 
C14789
Service code 9786 0x263A A 1 UNSIGNED_8 1 
C14850
All words from drive to master 9725 0x25FD A 32 UNSIGNED_16 1
C14851
All words from master to drive 9724 0x25FC A 32 UNSIGNED_16 1
C14852
All words to the basic device 9723 0x25FB A 32 UNSIGNED_16 1
C14853
All words to the basic device 9722 0x25FA A 32 UNSIGNED_16 1
C14854
Length of ports mapped into receive
PDO
9721 0x25F9 A 1 UNSIGNED_8 1
C14855
Length of ports mapped into send PDO 9720 0x25F8 A 1 UNSIGNED_8 1
C14860
Settings 9715 0x25F3 A 2 UNSIGNED_8 1
C14861
Bus status 9714 0x25F2 E 1 BITFIELD_16
C14862
Counter 9713 0x25F1 A 4 UNSIGNED_16 1
C14863
Active baud rate 9712 0x25F0 E 1 UNSIGNED_8 1
C14880
Monitoring Reaction 9695 0x25DF A 1 UNSIGNED_8 1 
C14881
Response time if the INTERBUS
communication is interrupted
9694 0x25DE E 1 UNSIGNED_16 1 
C14885
Clear process data 9690 0x25DA E 1 UNSIGNED_8 1 
C14892
PCP data length 9683 0x25D3 E 1 UNSIGNED_8 1 
C14893
Process data length 9682 0x25D2 E 1 UNSIGNED_8 1 
C14894
Baud rate 9681 0x25D1 E 1 UNSIGNED_8 1 
C14900
Firmware product type 9675 0x25CB E 1 VISIBLE_STRING
C14901
Firmware compilation date 9674 0x25CA E 1 VISIBLE_STRING