Display of operating data, diagnostics
Diagnostics
10
Function library
10.16
10.16.2
L
10.16-4
EDS82EV903-1.0-11/2002
10.16.2 Diagnostics
Display codes for diagnostics
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0093* Controller type xxxy Only display
• xxx = Power taken from nameplate (e.
g. 551 = 550 W)
• y = Voltage class (2 = 240 V, 4 = 400 V)
C0099* Software version x.y Only display
x = Main version, y = Index
C0161* Active error
Display history buffer contents ^ 11.1-1
C0162* Last fault
• Keypad: three-digit, alpha numerical
C0163* Last but one f ault
fault detection
C0164* Last but two fault
•
eypa
:
au
num
er
C0168* Actual fault History buffer displays ”active error”
• Keypad: three-digit, alpha numerical
fault detection
• 9371BB keypad: LECOM f ault number
^ 11.1-1
C0179* Power-on time {h} Only display
Total time mains on
C0183* Diagnostics
0 No fault
Only display
102 TRIP active
104 Message ”Overvoltage ( OU)” or ”Undervoltage (
LU)” a ctive
142 Pulse inhibit
151 Quick stop active
161 DC-injection brake active
250 Warning active
C0200* Software ID
number
Only PC display
x = Main version, y = Subversion
82S8212V_xy000 8200 vector 0.25 ... 11 kW
82S8212V_xy010 8200 vector 15 ... 90 kW
C0201* Software
generation date
Only PC display
C0202*
Software ID
Output to keypad as string in 4 parts à 4 characters Only keypad display
1
number
82S8
2 212V
3 _xy0 x = Main version, y = Subversion
4 zz 00 = 8200 vector 0.25 ... 11 kW
10 = 8200 vector 15 ... 90 kW
C0304
Service codes Modifications only by Lenze Service!
...
C0309
C0372* Function module
0 No function module
Only display
identification
1 Standard I/O or AS-i
2 System bus (CAN)
6 Other function module on FIF
e.g. application I/O, INTERBUS, ...
10 No valid recognition
Description