EasyManua.ls Logo

Lenze E84DGFCp Series - Parameter Data Transfer; Addressing and Data Channels (DP-V0;DP-V1)

Lenze E84DGFCp Series
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDS84DMOTPBUS EN 3.0 - 11/2011 L 41
Communication manual 8400 motec PROFIBUS
Parameter data transfer
Addressing of the parameter data
9 Parameter data transfer
The PROFIBUS communication unit supports the cyclic and acyclic transmission of
parameter data:
Cyclic DP-V0 parameter data are based on the DRIVECOM profile.
If the DP-V0 parameter data channel is active, it additionally occupies 4 words of the
input and output data.
The acyclic DP-V1 parameter data are based on the PROFIdrive profile (PROFIDrive (DP-
V1) in preparation)
9.1 Addressing of the parameter data
The parameter data are addressed via codes which are listed in a code table in this
documentation and in the corresponding documentation of your controller.
Parameter reference
( 81)
Addressing of Lenze parameters
In the case of the DP-V0 parameter data channel, the parameters of a device are not
addressed directly via Lenze code numbers, but via indices (bytes 3 + 4) and subindices
(byte 2).
The conversion is made via an offset (24575 / 0x5FFF):
–PROFIBUS-Index
dec
= 24575 - Lenze code numbers
–PROFIBUS-DP index
hex
= 0x5FFF - Lenze code number
hex
Example of C00105 (quick stop deceleration time):
–PROFIBUS-Index
dec
= 24575 - 105 = 24470
–PROFIBUS-DP index
hex
= 0x5FFF - 0x69 = 0x5F96
The parameter values are entered into the user data (bytes 5 to 8) of the telegram.

Table of Contents

Related product manuals