Configuration
Overview of monitoring functions
8
110
EDBCSXE040 EN 6.0
Possible responses
l Lenze setting
ü Setting possible
Monitoring
OffWarningMessageShort−circui
t brake TRIP
TRIPCode
DescriptionFault message
0079 PR5 Internal fault (EEPROM) ü l ˘ ˘ ˘
0095 FAN1 Fan monitoring (only for built−in units ECSEE) ü l ˘ ˘ ˘
0105 H05 Internal fault (memory) ü l ˘ ˘ ˘
0106 H06 Internal fault (power section) ü l ˘ ˘ ˘
0260
1260
2260
NodeGuard Trp
NodeGuard Msg
NodeGuard Wrn
"Life Guarding Event":
The power supply module as CAN slave does not receive a node guarding telegram
from the CAN master within the "Node Life Time".
C0384 l ˘ ü ü ü