EasyManua.ls Logo

Lenze ECSEE040 - Table of Attributes

Lenze ECSEE040
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
Table of attributes
11
152
EDBCSXE040 EN 6.0
11.2 Table of attributes
The table of attributes contains information required for communicating with the ECSxE
power supply module via parameters.
How to read the table of attributes:
Column Meaning Entry
Code Name of the Lenze code Cxxxx
Name Parameter short text Text
Index
dec
Index under which the parameter is addressed.
The subindex for array variables corresponds to
the Lenze subcode number.
24575 − Lenze code number
Only required for control via bus
system.
hex 5FFFh − Lenze code number
Data DS Data structure
E Single variable
(only one parameter element)
A Array variable
(several parameter elements)
DA Number of array elements (subcodes) Quantity
Data type Indication of the data type
BITFIELD_8 1 byte bit coded
BITFIELD_16 2 byte bit coded
BITFIELD_32 4 byte bit coded
INTEGER_8 1 byte with sign
INTEGER_16 2 bytes with sign
INTEGER_32 4 bytes with sign
UNSIGNED_8 1 byte without sign
UNSIGNED_16 2 bytes without sign
UNSIGNED_32 4 bytes without sign
VISIBLE_STRING ASCII string
Factor Factor for data transmission via bus system,
depending on the number of decimal positions
1, 10, 100, or 1000 1 º no decimal position
10 º 1 decimal position
100 º 2 decimal positions
1000 º 3 decimal positions
Access
R Read access ü Reading allowed
W Write access ü Writing allowed
CINH Controller inhibit required ü Writing only possible when controller is inhibited
Table of attributes
Code Designation
Index Data Access
dec hex DS DA Data type Factor R W CINH
C0001 Operating mode 24574 5FFE E 1 INTEGER_32 10000
ü ü
C0002 Load Lenze setting 24573 5FFD E 1 INTEGER_32 10000
ü ü ü
C0003 Save parameter set 24572 5FFC E 1 INTEGER_32 10000
ü ü
C0004 Selection of XT keypad status display 24571 5FFB E 1 INTEGER_32 10000
ü ü
C0009 LECOM device address 24566 5FF6 E 1 INTEGER_32 10000
ü ü
C0022 Max. charging current after power
supply enable
24553 5FE9 E 1 INTEGER_32 10000
ü ü
C0023 Peak current (peak) 24552 5FE8 E 1 INTEGER_32 10000
ü
C0024 Service code 24551 5FE7 E 1 INTEGER_32 10000
ü ü
C0028 Service code 24547 5FE3 E 1 INTEGER_32 10000
ü ü
C0029 Service code 24546 5FE2 E 1 INTEGER_32 10000
ü ü
C0031 Service code 24544 5FE0 E 1 INTEGER_32 10000
ü ü
C0040 Power supply enable − power supply
module
24535 5FD7 E 1 INTEGER_32 10000
ü ü
C0043 Reset fault message 24532 5FD4 E 1 INTEGER_32 10000
ü ü
C0050 Mains voltage (V
rms
) between phases
L1−L2
24525 5FCD E 1 INTEGER_32 10000
ü
C0051 Mains voltage (V
rms
) between phases
L2−L3
24524 5FCC E 1 INTEGER_32 10000
ü
C0053 DC−bus voltage (U
G
) 24522 5FCA E 1 INTEGER_32 10000
ü

Table of Contents