Technical data
General data and operating conditions
3
19
EDBCSXE040 EN 6.0
3 Technical data
3.1 General data and operating conditions
Standards and operating conditions
Conformity CE Low−Voltage Directive (2006/95/EC)
Approvals UL 508C Power Conversion Equipment
Underwriter Laboratories (File No. E132659)
for USA and Canada
Packaging (DIN 4180) Shipping package
Installation Installation in control cabinet
Mounting position Vertically suspended
Free space
above ³ 65 mm
below ³ 65 mm
With ECSZS000X0B shield mounting kit: > 195 mm
to the sides Can be mounted directly side by side without any clearance
Environmental conditions
Climate 3k3 in accordance with IEC/EN 60721−3−3
Condensation, splash water and ice formation
not permissible.
Storage IEC/EN 60721−3−1 1K3 (−25 ... + 55 °C)
Transport IEC/EN 60721−3−2 2K3 (−25 ... +70 °C)
Operation IEC/EN 60721−3−3 3K3 (0 ... + 55 °C)
l Atmospheric pressure: 86 ... 106 kPa
l Above +40 °C: reduce the rated output
current by 2 %/°C.
Site altitude 0 ... 4000 m amsl
l Reduce rated output current by
5 %/1000 m above 1000 m amsl.
l Over 2000 m amsl: use is only permitted in
environments with overvoltage category II
Pollution VDE 0110 part 2 pollution degree 2
Vibration resistance Accelerational stability up to 0.7 g (Germanischer Lloyd, general conditions)