Diagnostics
Diagnostics with Global Drive Control (GDC)
9
121
EDBCSXE040 EN 6.0
Parameter
C0061
Designation
Heatsink temperature
Data type: INTEGER_32
Index: 24514
dec
= 5FC2
hex
Display of the heatsink temperature
Display range (min. value | unit | max. value)
−3276.7 °C 3276.7
Parameter
C0062
Designation
Interior device temperature
Data type: INTEGER_32
Index: 24513
dec
= 5FC1
hex
Display of the interior temperature
Display range (min. value | unit | max. value)
−3276.7 °C 3276.7
Parameter
C0064
Designation
Device utilisation (I x t)
Data type: INTEGER_32
Index: 24511
dec
= 5FBF
hex
Display of the device utilisation (I x t) over the last 180 s
l C0064 > 100 % activates OC5−TRIP.
l TRIP−RESET is only possible if C0064 < 95 %.
Display range (min. value | unit | max. value)
0 % 65535
Parameter
C0065
Designation
External low−voltage supply (U
24
)
Data type: INTEGER_32
Index: 24510
dec
= 5FBE
hex
Display of the external low−voltage supply (U
24
)
Display range (min. value | unit | max. value)
−1638.3 V 1638.3
Parameter
C0066
Designation
Load of internal brake resistor
Data type: INTEGER_32
Index: 24509
dec
= 5FBD
hex
Display of the load of the internal brake resistor
Display range (min. value | unit | max. value)
0 W 65535
Parameter
C0093
Designation
Device identification (type)
Data type: INTEGER_32
Index: 24482
dec
= 5FA2
hex
Display of the device identification (type)
Display list Information
0 No/unknown power section
12 ECSxE012
20 ECSxE020
40 ECSxE040
Parameter
C0099
Designation
Firmware version
Data type: INTEGER_32
Index: 24476
dec
= 5F9C
hex
Display of the firmware version
Display range (min. value | unit | max. value)
0.0 25.5