Electrical installation
Power terminals
5
39
EDBCSXE040 EN 6.0
Cable cross−sections and screw−tightening torques
Cable type Wire end ferrule Possible cable
cross−sections
Tightening torque Stripping length
Terminal strips X21 and X22
Rigid ˘
0.2 ... 10 mm
2
(AWG 24 ... 8)
1.2 ... 1.5 Nm
(10.6 ... 13.3 lb−in)
5 mm for screw
connection
10 mm for spring
connection
Flexible
Without wire end
ferrule
0.2 ... 10 mm
2
(AWG 24 ... 8)
With insulated wire
end ferrule
0.25 ... 6 mm
2
(AWG 22 ... 10)
With insulated TWIN
wire end ferrule
0.25 ... 4 mm
2
(AWG 22 ... 12)
Shielded cables
The following factors decisively determine the effect of the shielded cables:
ƒ Good shield connection
Ensure a contact surface as large as possible
ƒ Low shield resistance
Only use shields with tin−plated or nickel−plated copper braids (shields with steel
braids cannot be used).
ƒ High overlap rate of the braid
At least 70 ... 80 % with 90° overlap angle
The ECSZS000X0B shield mounting kit includes a wire clamp and shield sheet.