4
EDBCSXE040 EN 6.0
Scope of supply
Position Description Quantity
ECSE... power supply module 1
Accessory kit with fixings according to the design ():
l "E" − panel−mounted device
l "D" − push−through technique
l "C" − cold−plate technique
1
Mounting Instructions 1
Drilling jig 1
Note!
The ECSZE000X0B connector set must be ordered separately.
Connections and interfaces
Position Description Detailed
information
X22 Connections
l External brake resistor
l DC−bus voltage
l PE
42
LEDs: Status and fault display
X1 Automation interface (AIF) for
l Communication module
l Operating module (XT keypad)
52
72
X2 PE connection AIF
X3 Not assigned
X4 CAN connection
l System bus (CAN)
l Interface for
– master control and other modules
– PC/HMI for parameterisation and diagnostics
53
X6 Connections
l Low−voltage supply
l Digital inputs and outputs
l Thermostat contacts
51
S1 DIP switch
l CAN node address (device address in the CAN network)
l CAN baud rate
95
X21 Mains connection 40
Status displays
LED
Description
Red Green
Off On Power supply module is enabled, no fault
Off Blinking Power supply module is inhibited (CINH), switch−on inhibit
Blinking, 1 Hz Off Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active
Blinking, 3 Hz Off Message active
Blinking, 1 Hz Blinking Warning active with inhibited module
Blinking, 1 Hz On Warning active with enabled module